Implant-based (Abutment) Case

For Abutment orders, two scanning types can be selected: Sectioned Model and Unsectioned Model. When selecting the Unsectioned Model scanning type, it is recommended to add additional die scanning steps to scan.

Create the Order

For steps to create an order, see Sectioned Model Case or Unsectioned Model Case.

Order Information

1 Click to enter the order page.
2 Fill in the blanks and select the doctor and the technician from the list. If there is no targeted doctors and technicians, click to add them.
3 Select Restoration as the dentistry type.
4 (Optional) Add notes.

Tooth Selection

1 Select Patient Mode.
2 Click the tooth to select the type of restoration.
3 (Optional)Click the slider to add scanning steps(pre-op scanning step and gingiva separately scanning node).
4 Click Custom Abutment(manual positioning) or Screw Retained(manual positioning) in Implant-Based.
5 Select restoration material.
6 Select the tooth color.
7 Click Finish.

Type Selection

1 Select Sectioned Model or Unsectioned Model.
2 Select Occlusion Type according to the reality.
3 Click Scan to start or click Save to save the order and scan it later.

Start Scanning

Total Jaw Scan

1 Follow the guidance on the interface to place the height adaptor, the fixture and the model.
2 Set the configuration in the camera window. For steps to set the configuration, see Parameters.
3 (Optional) Turn on additional functions. For more, see Function.

4 Click or press the space key to start scanning.

5 After scanning, move or rotate the cutting plane to cut the model.

6 Click to edit the model. For more, see Function.

7 Click to save the edit and return to the scanning interface.
8 Click to preview the scanned model; or click to rescan; or click to finish.

Lower Jaw Scan

1 Click or press the space key to start scanning.

2 If the scanned data is incomplete, click to add more data to the existing scan.
3 After finishing, cut and edit the scanned data for a cleaner scan.
4 Click to finish.

Upper Jaw Gingiva Scan

1 Click or press the space key to start scanning.

Note

: Improve the integrity of scanned data. This function is enabled by default when scanning gingiva.

2 If the scanned data is incomplete, click to add more data to the existing scan. For steps to add scan, see Function.
3 After scanning, cut and edit the scanned data according to reality.
4 click to finish.

Upper Jaw Scan

1 Click or press the space key to start scanning.

Note

:When scanning reflective objects such as abbutment and scanbodies, it is recommended to enable it to improve the scanning quality.

2 If the scanned data is incomplete, click to add more data to the existing scan.
3 After scanning, cut and edit the scanned data according to reality.
4 Click to finish.

Upper Jaw Gingiva Alignment

1 Check the automatic alignment.
2 (Optional) If the result is not optimal, click and align the scanned data manually. For steps to align, see Alignment Operation.

Automatic Alignment Manual Alignment

Die Scan - Upper Jaw

Note

For unsectioned orders, it is recommended to click on the step bar to add the Die Scan - Upper Jaw/Lower Jaw scan step.

1 Follow the guidance on the interface to place the model.
2 Adjust the brightness and the cutting height in the camera window.

3 Click or press the space key to start scanning.

Note

: enable by default to acquire abutment data.

4 If the scanned data is incomplete, click to add more data to the existing scan.
5 After scanning, cut and edit the scanned data for a cleaner scan.
6 Click to check the effect. Or click to finish.


Die Alignment - Upper Jaw

1 Check the automatic alignment and click to finish.
2 (Optional) If the result is not optimal, click and align the scanned data manually. For steps to align, see Alignment Operation.

Automatic Alignment Manual Alignment

Occlusion Alignment

1 Check the automatic alignment and click to finish.
2 (Optional) If the result is not optimal, click and align the scanned data manually. For steps to align, see Alignment Operation.

Finish Scanning

After finishing the scanning process,click on Go to Pre-design to edit the scanned data.