Skip to content

Multidie Case

Die Order

Create the Order

Order Information

1 Click to enter the order page.
2 Fill in the blanks and select the doctor and the technician from the list. If there is no targeted doctors and technicians, click to add them.
3 Select Restoration as the dentistry type.
4 (optional) Add notes.

Tooth Selection

1 Select Multidie Mode.
2 Click the hole in the fixture of the tooth die.
3 Select the type of restoration.

Note

● Click the right mouse button (RMB) to cancel the selected type of restoration one by one.
● Click Clear All to cancel all selected types.

4 Click Scan to start or click Save to save the order and scan it later.

Start Scanning

Die Scan

1 Follow the guidance on the interface to place the height adaptor and the model.
2 Set the configuration in the camera window.
3 (Optional) Turn on additional functions.
: Add details and process a high-quality scan.

4 Click or press the space key to start scanning.
5 After scanning, move or rotate the cutting plane to cut the model. Failure to remove the unnecessary jig data (the red part in below picture) may cause misalignment later.
6 Click to edit the model.
7 Click to save the edit and return to the scanning interface.
8 Click to preview the scanned model; or click to rescan; or click to finish.

Finish Scanning

After finishing the scanning process,click on Go to Pre-design to edit the scanned data.

Waxup Order

Create the Order

For steps to create a multidie order, see Multidie Case-Create the Order.

Start Scanning

Wax-up Scan

1 Follow the guidance on the interface to place the height adaptor and the model.
2 Set the configuration in the camera window.
3 (Optional) Turn on additional functions.
4 Click or press the space key to start scanning.
5 After scanning, move or rotate the cutting plane to cut the model.
6 Click to edit the model.
7 Click to save the edit and return to the scanning interface.
8 Click to preview the scanned model; or click to rescan; or click to finish.

Die Scan

1 Follow the guidance on the interface to place the height adaptor and the model.
2 For scanning details, see the last scanning step on Wax-up Scan.

Wax-up Alignment

1 Check the automatic alignment and click to finish.
2 If the result is not optimal, click and align the scanned data manually.

Finish Scanning

After finishing the scanning process,click on Go to Pre-design to edit the scanned data.