Interface¶
After the device is powered on, it defaults to the home page (except for first use), where you can view all project groups and the device status.
Home Page¶

-
Calibration
Displays the date of the most recent calibration. Tapto enter the calibration interface.
-
Status Bar
Displays information about the current device network, temperature, remaining battery, disk space, and system memory usage.-
: USB drive recognized.
-
: Network connection status. A weak Wi-Fi signal will affect wireless transmission speed.
-
: Hard drive used space and total space. When remaining space is less than 10 GB, the icon will turn red, suggesting to clean up local project group files and clear the cache.
: Memory usage ratio. When the ratio > 95%, the icon will turn red, indicating that data processing requires a large amount of memory, and it is recommended to create a new project for scanning.
: Device temperature. Red indicates that the temperature is too high. Pause scanning if the temperature exceeds the limit. Before calibration, warm the device.
: Warming up. Displayed while the device is in the preheating phase. Once warming up is complete, the icon reverts to the standard device temperature icon.
: Calibration Recommended. In a non-warming-up state, this icon appears if the current temperature deviates from the calibration temperature by the set threshold.
: Remaining Battery Level. The icon turns red when the charge level is ≤ 20%, indicating that charging or a battery replacement is recommended. Click the icon to view detailed battery bay status.
: Energy saving mode. The device is currently in energy-saving state, and will automatically enter this state when the device temperature is too high. At this time, the device's data processing rate will decrease.
-
-
Project Groups
Displays the names, creation times, and occupied space sizes of all project groups. -
Settings
In the settings, you can complete calibration, network settings, and general device settings. -
Tap to create a new project group. -
Use Template
Refer to Scan Template. -
Select
When there are project groups, you can tap Select to manage the project groups.
Control Center¶
Pulling down from the top of the screen will display the control center. Through the control center, you can quickly access device calibration and other settings.

-
Account Information
When not logged in, Log in is displayed. Tap to open the login interface.
After logging in, it shows the username and email. -
Settings
Tap to enter system settings. -
Shutdown
Taping will pop up a secondary confirmation menu, allowing for restart, reset and shutdown operations. -
Shortcuts
: Tap to enter the calibration interface. The calibration date will be displayed after successful calibration.
: Tap to enter Settings > Network Settings to manage Wi-Fi.
: Tap to enter Settings > General > Cast to select the mirroring device.
: Tap to switch between dark and light themes.
: Tap to enter the Resource Center.
-
Screen Brightness Adjustment
Drag the slider to adjust the screen brightness. -
Volume Adjustment
Drag the slider to adjust the media volume.
Settings¶
Tap Settings on the home page or the control center's to enter the Settings interface.

My Omni¶
Used to display user and device-related information.
User Information¶
When not logged in, the top of the page displays Log in. The login steps are as follows:
- Ensure the device is connected to the internet; if not, complete the network settings first.
- Tap Log in to enter the login interface.
- Enter your account (email) and password to complete verification.
- After successful login, the top of the page will display the user avatar, name, and email.
Device Information¶
-
Device Name
The model name of the device. -
Device Serial Number
The device serial number is the unique identifier for the device, which needs to be provided for after-sales service or technical support. -
Calibration Board SN
Used for calibration-related operations. -
Last Calibration
Displays the last calibration time of the device. You can tap the Calibration on the right to enter the calibration function interface and complete recalibration. -
Battery Compartment Information
Displays voltage difference for A and B battery compartments. Tap to view the temperature and voltage of each battery. -
Authorization Information
Display the device's authorization status and expiration time. -
Auto Inspect
Display the authorization status and expiration time of the inspect function.
Network Settings¶
Used to manage the device's Wi-Fi connection status and available network list. Through this page, you can view the currently connected network, change the Wi-Fi connection status, and select other available networks.
Hotspot¶
Through the hotspot, other devices can join the same network for casting or scanning via the FreeScan Omni software.
General¶
-
Temperature Control
When enabled, the device remains in a warm state during sleep to keep accuracy.Caution
Incomplete warming does not affect the use of calibration and scanning functions, but accuracy may be impacted.
-
Scan and Identify Calibration Board Code
When enabled, you need to scan the calibration board barcode before calibration. This prevents the use of incompatible calibration board. -
Scanning Distance Indication Method
Choose the method of distance indication, which can be either Histogram or Laser Line Indicator. -
Real-time Resolution Display
When enabled, the scan data will have higher resolution, but may take longer processing time. -
Partial Resolution Circle
The circle refers to the scan area in partial resolution mode. Changing the circle size changes the size of the scan area. -
Language
Tap to change the device language. -
Time Zone
Tap to change the device time zone. -
Auto Sleep
If the device has not processed data or has not been operated for the set duration, it will automatically enter sleep mode. Pressing the power button will wake the device. -
Cast
The screen mirroring function supports wirelessly transmitting the content on the scanner's screen to supported devices, such as smart TVs or computer monitors, using Wi-Fi or a hotspot.Caution
When using Wi-Fi for wireless connection, the mirroring device and the scanner must be connected to the same Wi-Fi; if using a wireless connection, the hotspot will be automatically enabled, and the mirroring device should connect to this hotspot.
-
Warm Up
After you turn it on, the device will start warming up. This process helps the scanner stay accurate and stable. You can set the allowed temperature difference between calibration and scanning. If the temperature changes too much,will appear in the status bar.
While warming up, you can choose fast warm-up mode. In this mode, the device projects laser lines to speed up the process and save time.
Caution
- Do not look directly at the laser source while the lasers are on.
- The device will automatically exit fast warm-up mode if you start calibrating or if you create or open a project.
-
DHCP
When enabled, the device will automatically assign network configuration parameters when connecting to PC software. -
Auto-Connect Dock Wi-Fi
Once turned off, the device will not automatically connect to the smart dock's WiFi when docked for charging. -
Volume
Tap to turn the device volume on/off or drag the bar to adjust volume. -
Dark Mode
Tap to choose between light theme or dark theme.
Help¶
You can view the QR code for this user manual and find the technical support center.
Storage¶
-
Storage
Displays the used storage space and remaining storage space of the device. -
Cache
The cache consists of local logs, images, and other temporary data generated during device use.
Tap Clear to permanently delete cache data.Note
Clearing the cache will not affect normal use.
Factory Default¶
Restoring factory default will reset the settings parameters and clear personal information and project data on the device. Please confirm whether you need to clear the data before proceeding.
Note
- If you choose Restore Scan Settings, the current settings parameters will be reset to their initial state.
- If you choose Factory Default, the current logged-in account and settings parameters will be reset to their initial state.
- All project group files can also be selected for synchronization clearing. Please ensure that important data is backed up.
About¶
In the About interface, you can view the current software version and firmware version of the device, as well as perform version updates.
Note
Before performing a version update, please ensure the following preparations are completed:
- Ensure the battery is at least 30% or connected to a charger.
- Please keep at least 10 GB of available space.
- Please connect to a stable Wi-Fi network.
- For data security, it is recommended to back up data.
- Tap Check for Updates, and the device will automatically check for available new versions.
- If a new version is available, About and System Update will display the
tag.
- Tap Update, and the system will start downloading the update package. Tap Update Log to view the update log.
-
After the download is complete, tap Install, and the system will automatically install the update package.
Note
After installation, the device will automatically shut down and restart. This process may take a few minutes, please be patient.
-
Check whether the system version has been successfully updated.
You can also view the Privacy Policy and User Experience Program.