Connect/Disconnect the Scanner¶
Caution
● Ensure the supplied software programs are installed on your computer before the connection.
● If the accuracy of the equipment decreases or if the equipment does not work properly, please consult technical support promptly.
● Install the scanner in accordance with the instructions stated in the Manual.
● Use the scanner only in dental laboratories, dental clinics, and equivalent environment.
● Do not install, place, and use the scanner in dusty and damp environment or in the areas of temperature extremes or in direct sunlight.
● Prepare a flat surface, e.g. your desk, for the scanner and the cradle. Do not place them on a slanted surface.
● Before the installation is completed, do not plug the power adapter into the wall outlet or turn on the scanner until you are instructed to do so.
● Always hold the scanner firmly when lifting from the stand or when using the scanner. Do not shake the scanner.
● Always return the scanner to the cradle when it is not in use. Do not place the scanner in heated or wet surfaces as this can cause damage to the scanner.
● It is normal that the scanner gets warm when in use. Do not block the ventilation holes on the bottom of the scanner. If the scanner overheats, the scanner will stop working.
● Ensure that you use only the supplied power adapter, power cable, and USB cable.
Follow the steps below to complete the connection:
1 Push the scanner tip hard to the scanner main body to ensure firm attachment.
2 Connect the scanner cable to the USB 3.0 repeater.
3 Connect the USB 3.0 repeater to the USB 3.0 port on your PC.
4 Insert the power plug of the supplied power adapter into the power port on the cradle, and plug the power adapter into a wall outlet.
5 Click the shortcut icon of IntraoralScan on the desktop to launch the software.
Caution
● Do not attempt to directly disconnect the scanner by removing the power cable and USB cable.
● Do not roll the cable over the handle of the scanner or even create any sharp bends in the cable after you disconnect the scanner.
Follow the steps below to safely disconnect the scanner:
1 Quit the IntraoralScan scanning software.
2 Disconnect the scanner USB 3.0 cable from the USB 3.0 repeater.
3 Disconnect the other port of the USB 3.0 repeater from the computer
4 Right-click the Safely Remove Hardware icon on Windows taskbar and select Eject Flash Drive.
5 Unplug the USB flash drive and keep it in a safe place for future use.
6 Unplug the power adapter from the wall outlet and remove the power plug from the power port on the cradle.