EINSTAR2 features hybrid light sources and a wireless design, delivering vivid full-color capture for professional-grade 3D scanning with ease. From small figurines to full-body scans, from indoor setups to outdoor adventures, both professionals and hobbyists can quickly and easily complete 3D scanning with EINSTAR2.

Packing List

Col


Einstar2 3D Scanner

Col

Battery (Consumable)

Battery Compartment (Consumable)

Battery Compartment Charging Cable (Consumable)

Col

Calibration Board Holder

Calibration Board

Col

USB-C Data Cable

Power Adapter

Col

3 mm and 6 mm Markers

Col

Packing List

Note

If you need to clean the device housing, gently wipe it with a soft cloth. Do not use chemicals or alcohol.

Battery Specifications and Requirements

Specification Description
Battery Type Rechargeable lithium-ion battery
Battery Length 75.4 ± 0.3 mm
Battery Diameter 21.7 ± 0.3 mm
Battery Voltage 3.6 V
Battery Capacity 5500 mAh
Cycle Life ≥ 400 times
Environmental Requirements Description
Operating Temperature Charging: 0 ~ 45℃
Discharge: -20 ~ +60℃
Storage / Transport Temperature -20 ~ +45℃ (less than 1 month)
-20 ~ +35℃ (less than 3 months)
-20 ~ +25℃ (less than 6 months)
Storage / Transport Relative Humidity ≤ 75%RH

Structure and Components

Col

Col


The status indicator shows the connection status or scanning status of the scanner.

Col

Non-scanning status

  • Blue (blinking): The scanner is not connected to the software.
  • Green (solid): The scanner is connected to the software.
  • Yellow (blinking): Firmware update in progress.

  • Col

    Scanning status

  • Blue (solid): The scanning distance is too far.
  • Light blue (solid): The scanning distance is a bit far.
  • Green (solid): The scanning distance is proper.
  • Yellow (solid): The scanning distance is a bit close.
  • Red (solid): The scanning distance is too close.


  • The button controls power on/off, whether to start calibration, scanning status, light source switching, and invoking the menu.

    Col

    • Press and hold for about 2 seconds until the status indicator and battery indicator light up, indicating that the scanner is powered on.
    • Press and hold for about 5 seconds until the indicators and battery indicator go out, indicating that the scanner is powered off.

    Col

    Col

    • Scanning interface:

      • Tap to start scan preview; tap multiple times to cycle through start scanning and pause scanning.
      • Double-tap to invoke the menu and select the control scope of the / buttons (black-and-white camera brightness adjustment, texture camera brightness adjustment, or view zoom).

    Col

    Menu window

    The / buttons control the brightness increase/decrease of the black-and-white camera and texture camera.

    Col

    • Tap / to increase or decrease the camera brightness or zoom in/out the model view.
    • / Double-tap to directly switch to the highest/lowest brightness level or the maximum/minimum model view.
    • Press and hold / to continuously increase or decrease the camera brightness or continuously zoom in/out the model view.

    Col


    • Green (solid): Battery level > 50%.
    • Yellow (solid): 10% < battery level ≤ 50%.
    • Red (solid): Battery level ≤ 10%.

      Note

      When the scanner is charging via the USB-C data cable, the battery indicator changes from solid to breathing.

    • Red (blinking): The scanner temperature is too high.

      Note

      If the scanner is powered on with insufficient battery, the battery indicator blinks red quickly and the scanner shuts down automatically.

    Col

    Please open the battery compartment and insert the battery before use.

    Caution

    Please place the battery correctly according to the positive and negative directions shown in the diagram.

    Col

    Heat vents of the scanner. Do not block the heat vents while the scanner is working.

    Col

    The scanner can be connected to a computer via the USB-C data cable for wired scanning or charging.

    Col